ULTRA 600 PIPE SPECIFICATION GUIDE

ULTRA 600 WORKING PRESSURE LISTING (NEW PIPE) METRIC

777 MARITIME DRIVE | P.O. BOX 308 PORT WASHINGTON, WI 53074 USA WWW.ULTRATECHPIPE.COM 1-262-284-7800 | 1-800-626-8243 UT ‐ SALES@ULTRATECHPIPE.COM

ULTRA 600 NOMINAL WALL (mm)

ULTRA 600 TOLERANCED WALL (-12.5%) (mm)

WORKING PRESSURE 3 TO 1 SAFETY FACTOR (bar)

WORKING PRESSURE 4 TO 1 SAFETY FACTOR (bar)

WORKING PRESSURE 5 TO 1 SAFETY FACTOR (bar)

ULTRA 600 PART NUMBER

ULTRA 600 NPS (mm)

PP2527H

65

7.01

6.13

316.6

237.4

189.9

PP3030H

80

7.62

6.67

280.5

210.4

168.3

PP4023H

100

6.01

5.26

168.2

126.1

100.9

PD4033H

100

8.55

7.48

243.1

182.3

145.8

PP5025H

125

6.55

5.73

147.4

110.6

88.4

PE5037H

125

9.52

8.33

217.6

163.2

130.6

PF5050H

125

12.7

11.11

295.1

221.3

177.0

PP6028H

150

7.11

6.22

134.0

100.5

80.4

PE6043H

150

10.97

9.60

210.2

157.6

126.1

PD8032H

200

8.17

7.15

117.9

88.4

70.7

PF8050H

200

12.7

11.11

185.9

139.4

111.5

PE1036H

250

9.27

8.11

107.0

80.2

64.2

PF1050H

250

12.7

11.11

147.9

110.9

88.7

PE1237H

300

9.52

8.33

92.3

69.2

55.4

PF1250H

300

12.7

11.11

124.0

93.0

74.4

PE1437H

350

9.52

8.33

83.9

62.9

50.3

PF1450H

350

12.7

11.11

112.7

84.5

67.6

PE1637H

400

9.52

8.33

73.3

54.9

43.9

PF1650H

400

12.7

11.11

98.2

73.7

58.9

PF1850H

450

12.7

11.11

87.1

65.3

52.2

PF2050H

500

12.7

11.11

78.2

58.7

46.9

PF2450H

600

12.7

11.11

65.0

48.7

39.0

Note: These working pressures are calculated for new pipe with no allowance for wear or corrosion. As soon as the pipe wall experiences loss from abrasion below the toleranced wall listing, the working pressure listed in the chart will no longer apply.